Simple measures to improve the performances of the backward/forward method for radial distribution network analysis

2005

In the paper, after having presented the general backward/forward methodology for radial systems analysis, the main changes that have been proposed in the past to improve their convergence and speed performance are shown. Some measures aimed at a further reduction of the number of iterations and calculation times are here described. In order to identify, among the available alternatives, the best methodology, in terms of precision and/or speed of convergence, some evaluations on networks taken from the literature have been carried out. The analysis of the attained results allows the definition, on the basis of specific features of the problem at hand, the most suitable configuration to be i…

Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaBackward/forward method Load flow analysis Power Distribution
researchProduct

Load flow analysis of radial distribution networks: New findings in backward/forward method

2005

In the paper, the backward/forward method for solving radial distribution networks is in details described. In particular it is examined considering the four main steps into which it can be divided: initialization of the state variables; backward sweep; forward sweep; identification of a convergence criterion. For each of these, except for the forward sweep, a new procedure is defined. In particular, a methodology for the identification of a starting solution that is as close as possible to the desired one is proposed; the backward phase is modified for the evaluation of the branch currents and a new convergence criterion is proposed. The results of the application of the proposed methodolo…

Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaBackward/forward method Load flow analysis Radial distribution networks
researchProduct

An Innovative Measurement Approach for Load Flow Analysis in MV Smart Grids

2016

This paper proposes a novel measurement procedure for load flow analysis in medium voltage (MV) smart grids. The new approach is based on power measurements at low voltage (LV) side of MV/LV distribution substations. Such measurements are carried out by means of power quality analyzers. If compared with the load flow methods based on measurements at the MV side, the proposed approach has a lower cost and it offers an equally reliable measurement system. The proposed algorithm takes the basic concept of the current summation backward/forward method; some modifications are introduced to use LV load powers measurements. To this aim, the MV/LV power transformer is properly modeled and taken int…

EngineeringGeneral Computer Science020209 energy02 engineering and technologyload flow analysispower system monitoring0202 electrical engineering electronic engineering information engineeringElectronic engineeringPower-flow studyMATLABSimulationcomputer.programming_languagebusiness.industrySystem of measurement020208 electrical & electronic engineeringAdvanced metering infrastructure load flow analysis power quality analyzer (PQA) power system measurements power system monitoring smart grid (SG).AC powerpower quality analyzer (PQA)power system measurementsPower (physics)smart grid (SG)Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSmart gridAdvanced metering infrastructurebusinesscomputerLow voltageSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Some improvements in solving radial distributions networks through the backward/forward method

2005

In the electrical radial distribution networks analysis, the backward/forward method shows good features in terms of robustness, independence from load nature, small use of hardware resources and limited calculation time. In the present paper, some procedures to improve the b/f method with the aim of reducing the calculation time are presented. The adopted procedures regard the choice of the initial values of the nodes voltages and the way in which the convergence criterion is applied. The results of some tests carried out on some electrical test systems here reported have shown the efficiency of the proposed methodology in terms of calculation time reduction, especially when solving heavil…

Mathematical optimizationEngineeringbusiness.industrySystem testingAC powerAutomationlaw.inventionSettore ING-IND/33 - Sistemi Elettrici Per L'Energiasymbols.namesakeCapacitorlawRobustness (computer science)symbolsPower-flow studybusinessBackward/forward method Load flow analysis Power DistributionNewton's methodVoltage2005 IEEE Russia Power Tech
researchProduct

An Efficient Procedure for Solving Radial Distribution Networks through the Backward/Forward Method

2005

In the paper, after having presented the general backward/forward methodology for radial systems analysis, a new b/f procedure showing some interesting features that improve its performance in terms of convergence speed and calculation effort is presented. The features that fundamentally are responsible for such improvements concern the main steps of the b/f procedure. The starting voltage profile solution is different from the flat profile and is suitably modified. In the backward phase and starting from the second iteration, the branch currents variations due to the loads changes are evaluated; the latter variations are calculated on the basis of the difference of nodal voltages at the be…

Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaBackward/forward method Load flow analysis Power Distribution
researchProduct

A simplified approach for load flow analysis in MV smart grids based on LV power measurements

2017

This paper presents a simplified approach for load flow analysis in medium voltage (MV) distribution networks. It is a power summation Backward/Forward (B/F) algorithm, based on measurements of active and reactive powers at low voltage (LV) side of MV/LV distribution substations. The proposed solution allows achieving good accuracy, computational efficiency and fast convergence. In order to verify the algorithm performances, simulation studies are carried out in the case of a real test system, i.e. the distribution grid of Favignana Island (Mediterranean Sea, Italy). The compatibility between simulations results and power measurements at the MV bus bars of the generating substation shows th…

EngineeringBusbar020209 energyBiomedical EngineeringAdvanced metering infrastructure (AMI)Smart grid02 engineering and technologyload flow analysisControl theory0202 electrical engineering electronic engineering information engineeringElectronic engineeringPower-flow studyInstrumentationPower system monitoringbusiness.industry020208 electrical & electronic engineeringAC powerSmart gridPower system measurementSignal ProcessingLoad flow analysiAlgorithm designPower system measurementsDistribution gridPower quality analyzers (PQA)businessSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageVoltage2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

An analytical model for PQ sources in backward/forward methods for distribution networks analysis

2004

In this paper a model of PQ sources useful for distribution systems analysis is developed. In the considered systems there are, in addition to HV/MV sources, other PQ buses, namely active and reactive power supply nodes (Vδ nodes). The general solution strategy is an iterative forward/backward method, in which the state variables are the node voltages. If it is weakly meshed, the network is turned into radial by means of cuts and compensation currents. After the presentation of the general problem, the equations expressing the unknowns for the PQ nodes are treated in detail. These equations belong to the backward sweep of the algorithm. The methodology has been implemented and applied so as…

Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaDispersed generation Iterative methods Load flow analysis Distribution networks
researchProduct

Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid

2015

This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…

Engineeringbusiness.industryPower system monitoringPower factorSmart gridAC powerLoad flow analysisPower quality analyzerConstant power circuitPower (physics)Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaPower system measurements load flow analysis power system monitoring smart grid power quality analyzer advanced metering infrastructureMeasurement uncertaintyAdvanced metering infrastructureVoltage regulationPower-flow studyPower system measurementsbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheLow voltageAlgorithm
researchProduct

Uncertainty evaluation in load flow analysis: real MV distribution networks case studies

2018

This work investigates the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. The considered algorithm is a simplified load flow algorithm (LFA), developed by authors, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). In the viewpoint of a real implementation, to reduce monitoring system costs, the LFA makes use of low voltage (LV) load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on LFA input quantities (load powers a…

power system monitoringPower system measurementpower quality analyzers (PQA)load flow analysismart gridadvanced metering infrastructure (AMI)Settore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Measurement uncertainty impact on simplified load flow analysis in MV smart grids

2018

This work is focused on the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. In more detail, the paper presents the uncertainty evaluation of a simplified load flow algorithm, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). To reduce the costs of the monitoring system, the load flow algorithm makes use of LV load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on the algorithm input quantities (load powers and slack b…

MonitoringBusbar020209 energyMonte Carlo methodElectric load flowAdvanced metering infrastructure (AMI)02 engineering and technologySmart gridUncertainty evaluationElectric power system measurementPower quality analyzerSlack buspower system monitoringElectric power transmission networksControl theory0202 electrical engineering electronic engineering information engineeringpower quality analyzers (PQA)MedicinePower-flow studyload flow analysiSafety Risk Reliability and QualityInstrumentationbusiness.industryElectric power distributionPower (physics)Smart gridPower system measurementMeasurement uncertaintybusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct